Brand: PValley
Model: SWP-42T5
Country of Origin: China
Assemble/Manufacturer: Bangladesh
General Specification:
Body Material:
Printed Front Side Sheet
Sheet Type: Digital
Country of origin: China
Feature:
- Sheet number 26
- Storage Printed temperature 300°c
- Color White/Silver
Hard Round support board or Plastic Sheet
Sheet Type: Digital
Country of origin: Pakistan
Feature:
- Sheet thickness 10mm
- Two-Part Combination (Transparent/white)
- UV Printout
Safety Breaker
Brand: Hyundai
Country of origin: South Korea
Feature:
- Human Body Sense safety
- Current error detection range is 20mA
- Soft tripping
- Low noise cut off
Panel Box
Brand: Madhav Enterprise
Country of origin: Indian
Features:
- Shape: Rectangular
- Surface Finish: Smooth
- High-quality raw material
Best structure
Brand: Altech
Country of origin: Bangladesh
Feature:
- Sheet thickness 5mm
- Sheet (Silver/white)
- Square Shape
Power Monitoring
Brand: UNI-T
Country of origin: China
Feature:
- Self-operating voltage 12V
- Self-Consumption Current 20mA
- Power Nature
Use Connector
Brand: ZHT
Country of origin: China
Feature:
- Banana Female Connector Diameter 13mm
- Banana Male Connector Diameter 4.5mm
Working area:
- Working area: 40 * 25 inch
Technical Specification:
- Power Supply:
- Rated Input Voltage: 380 V AC Three Phase 4-wire;
- Rated Output Voltage: 380 V AC Three Phase 4-wire;
- Safety: Short-Circuit Protection, Emergency Stop, Earth Facility Error Current protection.
Short-Circuit Protection
- Fast-acting MCB/fuse provided at input and output stages
- Protects equipment and users from over-current and short-circuit faults
- Automatic disconnection of supply during fault condition
Emergency Stop
- Prominent Emergency Stop (E-STOP) push button on front panel
- Manually cuts off complete power supply instantly
- Red mushroom-head type with twist-to-release mechanism
Earth Leakage Protection (ELCB/RCCB)
- Built-in Earth Leakage Circuit Breaker (ELCB/RCCB)
- Rated sensitivity: 30 mA (human safety standard)
- Rated current: 30–63 A (as per system requirement)
- Trip time: ≤ 30 ms
- Provides protection against earth fault leakage current
- Automatically disconnects supply during insulation failure or earth fault
- Ensures operator safety and prevents electric shock
- Multiple Parameter Protection Relays: Device type Digital
- Digital Over-Voltage, Under-Voltage & Over-Current Protection Relay with integrated breaker control
- Continuously monitors line voltage and load current parameters
- Adjustable over-voltage, under-voltage, and over-current trip settings
- High-accuracy digital measurement with LED/LCD display indication
- Automatic trip command to circuit breaker during abnormal conditions
- Fast response time for effective equipment and user protection
- Manual and automatic reset facility
- Visual fault status and alarm indication
- Suitable for single-phase / three-phase systems (as per configuration)
- Ensures safe operation and prevents damage due to electrical faults
Switching Devices: MCBs (Miniature Circuit Breakers) & Related Others.
- Rated operating voltage: 230/415 V AC
- Rated current range: 6 A to 63 A
- Tripping characteristics: Type B / Type C / Type D
- Breaking capacity: 6 kA / 10 kA (as per IEC standard)
- Thermal trip for overload protection
- Magnetic trip for short-circuit protection
- Single-pole / Double-pole / Triple-pole / Four-pole configurations
- DIN-rail mountable, modular construction
- Operating frequency: 50/60 Hz
- Mechanical endurance: ≥ 10,000 operations
- Electrical endurance: ≥ 6,000 operations
- Compliance with IEC 60898 / IS standards
- Operating temperature range: –5 °C to +55 °C
- Loads: Resistive, Inductive and Capacitive.
Resistive Load
- Three selectable resistance values
- High-power wire-wound resistors
- Suitable for AC/DC operation
Inductive Load
- Three selectable inductance values
- Laminated core / choke type inductors
- Designed for AC operation
Capacitive Load
- Three selectable capacitance values
- Power-grade polypropylene capacitors
- Suitable for AC operation
- Measurement: Digital Meters (Voltmeter, Ammeter, Energy Meter),
Voltmeter
- Measuring range: AC/DC (as applicable)
- Accuracy class: ±1.0 / ±0.5
- Display type: Analog / Digital
- Input impedance: High impedance
- Rated frequency: 50/60 Hz
- Over-range protection provided
Ammeter
- Measuring range: AC/DC (as applicable)
- Accuracy class: ±1.0 / ±0.5
- Display type: Analog / Digital
- Current sensing: Shunt / CT based
- Rated frequency: 50/60 Hz
- Over-current protection provided
Energy Meter
- Measurement type: Active energy (kWh)
- Voltage rating: 230 V / 415 V AC
- Current rating: 5–20 A / 10–40 A
- Accuracy class: Class 1.0 / Class 0.5
- Frequency: 50/60 Hz
- Digital LCD display
- Pulse / LED energy indication
- Complies with IEC standards
- Motor Protection: Specific modules for Motor Protection
- Dedicated Motor Protection Module for AC induction motor safety
- Protection functions:
- Over-current protection, Thermal protection, Under-voltage protection, Over-voltage protection
- Single phasing / phase failure protection
- Phase sequence protection
- Adjustable trip current and time delay settings
- Thermal memory function for motor heating effect
- Automatic and manual reset facility
- Trip status LED / digital indication
- Output relay contact for contactor control
- Suitable for single-phase / three-phase motors (as per configuration)
- Rated supply voltage: 230 V / 415 V AC, 50/60 Hz
- Conforms to IEC motor protection standards
- Control Board:
- Three Phase Energy Meter: 1 EA;
- BAS Bar: 4EA;
- Circuit Breaker: 3EA (10Amp);
- Cartridge Fuse: 3EA (10Amp);
- HRC Fuse: 3EA (16Amp);
- Thermal Overload Relay: 1 EA;
-
- Digital Timer: 2EA;
- Magnetic Contractor: 3EA;
- Selector Switch:2 EA;
- Relay: 2 EA;
- Phase fault Relay: 1EA;
- Other Devices:
- 4mm safety jack Connection facility;
- Short Circuit Protection Facility;
- 1 Phase AC Load Connection Facility (Power Socket);
- Size: 5 Feet x 1.5 Feet x 2.5 Feet (Length x Width x Height);
Accessories:
- 4mm safety banana plug -1 Set;
- Three Phase Induction Motor, 2HP (Star-Delta)/Experimental – 1 pcs;
- 3 Phase Variac -1 Pcs
- Power Cord: 01 set
- Connecting Wire & Cable
- Complete 5 days of Training Included
- User Manual or User Guide
Protection:
Under voltage, Supply overvoltage, Drive overload, Ground fault, etc.




Reviews